Layout studs
Layout studs = (wall length in inches ÷ spacing, rounded up) + 1
Dividing the length by the spacing counts the gaps between studs. The + 1 adds the stud at the far end, so both end studs are included. This is the same rule the deck calculator uses for joists.
Extra studs
- Corners: + 2 per corner for a 3-stud corner, or + 1 for a 2-stud advanced framing corner. The wall's end stud is already a layout stud.
- Wall intersections (T): + 2 per intersection for a stud channel, or + 0 with ladder blocking.
- Windows and doors: king studs = openings × 2 sides × kings per side, and jack studs = openings × 2 sides × jacks per side. The default is 1 king and 1 jack per side.
Layout studs are not subtracted for openings. The layout studs that fall inside a window or door are cut into cripple studs above the header (and below the sill for windows), so the count already pays for that material.
Studs to order, plates and headers
Studs to order = (layout + extras + kings + jacks) × (1 + spares % ÷ 100), rounded up
- Plate linear feet = wall length × plate rows (no spares). A double top plate and a single bottom plate is 3 rows.
- Plate boards for each board length = rows × (wall length × (1 + spares) ÷ board length, rounded up).
- Header linear feet = openings × plies × (opening width + 2 × jacks per side × jack thickness) ÷ 12.
- Cripples (information only) = about openings × (opening width ÷ spacing, rounded down), doubled for windows. The real number depends on where the opening falls on the layout.
Not counted: blocking and fire blocking, ladder-blocking lumber, sheathing, nails, hold-downs, rim or band joists, and header sizing. The bottom plate is not shortened at doors, because plates are usually laid full length and cut out after the wall is raised.